Capacity, COP, kW/TR and EER of a water-cooled chiller: IPLV-style part-load efficiency, Carnot fraction, approaches and UA for fouling, and design, actual and proposed cases with a condenser water what-if.
USD 39 one-time purchase
Download the sample report (PDF)
Need it once? Use it online: check your data free, unlock results from USD 9 for 3 runs.

What it does
Cooling capacity
From the water side or the refrigerant side; both shown when entered, and the difference flags a metering problem.
COP, kW/TR and EER
From measured compressor power or motor amps, volts and power factor, with the load as a share of rated capacity.
IPLV-style part-load efficiency
Weighted from four part-load points, aligned with the publicly documented AHRI 550/590 weighting, or with your own site weights.
Carnot fraction
On refrigerant saturation temperatures or water temperatures, to separate a poor machine from a high lift.
Approaches and UA
Evaporator and condenser approach, log-mean temperature difference and effective UA against design for tube fouling checks.
Condenser water what-if
The effect of condenser water temperature and chilled-water setpoint on compressor power, as a table and chart.
Built for engineers
- Visible formulas — nothing hidden, so you can check every step.
- Fully referenced — methods from the standard references, checked against their published worked examples.
- Safe to share — sheets are protected against accidental edits, with an open password so you can still customise.
- Built-in input checks — clear warnings for impossible inputs and values outside typical ranges.
For engineering estimates; verify against site data. Code-based methods are aligned with the publicly documented procedure; they are not a licensed reproduction or a certification.
Preview the workbook
Real pages from the workbook with its built-in example loaded (example data, not a measured plant). Choose a page below, or select the large image to enlarge it.
Specification and checks
| Format | Excel workbook (.xlsx), no macros |
| Version | v1.0 |
| Works in | Excel 2010 or later, Windows and Mac |
| Units | SI, US and British, mixed freely |
| Includes | Guide tab with method and references, calculator, print-ready report |
| Checked against | All 32 combinations of the five method selectors, 14 unit-system variants and 55 edge cases against an independent Python model (IAPWS-IF97 water properties); results agree within 1e-9 relative. |
| Free tools | Browse the free calculators |
Online tool or Excel workbook?
| Online tool | Excel workbook (this page) | |
|---|---|---|
| What it does | The same sheet as the Excel workbook, run in your browser | Capacity, COP, kW/TR and EER of a water-cooled chiller: IPLV-style part-load efficiency, Carnot fraction, approaches and UA for fouling, and design, actual and proposed cases with a condenser water what-if. |
| Cost | Check your inputs free. Results: 3 runs for USD 9, or every online tool for USD 15 a month (USD 99 a year) | USD 39 once, yours to keep |
| Input checks and findings | Every input checked; findings with the unlocked results | Every input checked, with findings and recommendations |
| Report for your calculation file | Printable results sheet | Print-ready report with your plant, tag, document number, revision and sign-off |
| Formulas | Method described in the guide | Every formula visible in its cell |
| Save, edit and rerun your cases | Each run separately | Yes: keep and edit your own file |
| Works offline, on a plant PC | No, needs the internet | Yes: Excel 2010 or later, Windows and Mac |
Online access and the Excel workbook are separate licences: one does not include the other.
Compatibility, licence and support
| File | Excel workbook (.xlsx), no macros, version v1.0; works in Excel 2010 or later on Windows and Mac. Sheets are protected against accidental edits, with an open password so you can customise. |
| Licence | Single user. A team licence (up to 5 named users) is 3 × the shop price; site licences on request — licence terms. |
| Updates | Updates to this major version are included; download them again from the link in your receipt. |
| Support | Email [email protected] with your order number — questions on the method, your inputs or your results are welcome. |
| Refunds | If the tool does not work as described, or has an error we cannot fix, email [email protected] with your order number within 14 days of purchase and we will refund you in full. Refunds are not offered for a change of mind once a file has been downloaded. Read the full refund policy. |