Home › Shop › Cleanroom HVAC Load and Air Changes
Excel tool

Cleanroom HVAC Load and Air Changes

Supply air and recovery time per room, sensible and latent loads, fresh-air load, leakage, fan power, coil and reheat duties and annual energy for up to eight cleanrooms.

A single design-point screen for the air handling of a cleanroom suite of up to eight rooms on one air-handling unit. For each room you enter the floor area and height, the air changes per hour for its cleanliness class, the pressure differential it is held at, the leakage (gap) area and the occupants, equipment, lighting and other heat gains. You enter one room design condition, the outdoor design condition and the coil data, and the tool returns the whole air-side picture.

USD 39 one-time purchase

  • Excel workbook (.xlsx), no macros, version v1.0
  • Excel 2010 or later, Windows and Mac
  • Instant download after payment; updates to this major version included
  • Single-user licence; team and site options
  • Refund if it does not work as described or has an error we cannot fix: contact support within 14 days of purchase — full refund policy
Cleanroom HVAC Load and Air Changes — sample pages

What it does

Supply air per room

Supply air per room from the air changes you choose, and the total for the unit, with the air changes on the whole suite volume.

Recovery (clean-up) time of

Recovery (clean-up) time of every room from the dilution equation, t = ln(ratio)/(air changes × mixing effectiveness), and the air changes a recovery-time target would need.

Room sensible and latent

Room sensible and latent loads from people, equipment, lighting and your own gains; the supply air temperature each room needs and the zone reheat for the warmer rooms.

Leakage out of each

Leakage out of each pressurised room through its gaps by the orifice equation, Q = Cd A √(2 Δp/ρ), and the fresh air needed to make up leakage plus exhaust.

Fresh-air flow and load

Fresh-air flow and load, fresh air per person, fan electrical input, specific fan power and the fan's temperature rise.

Cooling-coil and reheat duties

Cooling-coil and reheat duties for two air-handling arrangements — one coil for all the supply air, or a separate fresh-air unit with a dry coil — with the condensate removed, the coil leaving condition and the room humidity achieved.

Built for engineers

  • Visible formulas — nothing hidden, so you can check every step.
  • Fully referenced — methods from the standard references, with the book, edition and page named in the Guide tab.
  • Safe to share — sheets are protected against accidental edits, with an open password so you can still customise.
  • Built-in input checks — clear warnings for impossible inputs and values outside typical ranges.

For engineering estimates; verify against site data. Code-based methods are aligned with the publicly documented procedure; they are not a licensed reproduction or a certification.

Preview the workbook

An illustration of the sheet layout of this workbook, not a screenshot of calculated results. Select the image to enlarge it. For questions before you buy, email [email protected].

Cleanroom HVAC Load and Air Changes Excel workbook sample pages
Layout illustration (not a results screenshot).

Specification and checks

FormatExcel workbook (.xlsx), no macros
Versionv1.0
Works inExcel 2010 or later, Windows and Mac
UnitsSI, US and British, mixed freely
IncludesGuide tab with method and references, calculator, print-ready report
Checked againstChecked against an independent Python model (IAPWS-IF97 water properties from the iapws package, a root search for the dew point, all equations re-derived) in 154 recalculated runs: the default case, 30 selector combinations, SI, US, British and industry units on four cases, result-unit switching, and 37 valid and 68 invalid edge cases; about 5,300 values compared, 0 formula errors in LibreOffice.
Free versionBrowse the free calculators

Compatibility, licence and support

FileExcel workbook (.xlsx), no macros, version v1.0; works in Excel 2010 or later on Windows and Mac. Sheets are protected against accidental edits, with an open password so you can customise.
LicenceSingle user. A team licence (up to 5 named users) is 3 × the shop price; site licences on request — licence terms.
UpdatesUpdates to this major version are included; download them again from the link in your receipt.
SupportEmail [email protected] with your order number — questions on the method, your inputs or your results are welcome.
RefundsIf the tool does not work as described, or has an error we cannot fix, email [email protected] with your order number within 14 days of purchase and we will refund you in full. Refunds are not offered for a change of mind once a file has been downloaded. Read the full refund policy.