Home › Free calculators › Thermal oil system basics
Free calculator

Thermal oil system basics

Circulation rate from heat duty and temperature difference, expansion tank sizing, film temperature check and pipe velocity for common thermal oils.

Inputs

Units:
Heat duty and temperatures
kW
Thermal oil
kJ/(kg·K)
kg/m³
Pipe velocity check (optional)
Expansion tank (optional)
/°C
Film temperature check (optional)
kW/m²
W/(m²·K)

Results

Need this in Excel for your plant? See the PlantCalcKit Excel tools — print-ready reports, any units, visible formulas. Visit the shop →

Join PlantCalcKit — free

Be first to hear about new calculators, Excel tools and field guides — one short email when something new is ready. The calculators stay free with or without an account.

By joining you agree to our privacy policy. Unsubscribe or delete your details any time.

How this calculator works

A thermal oil (hot oil) system circulates a heat transfer fluid in a closed loop between a heater (fired or waste-heat) and one or more users. The circulation rate follows directly from the energy balance: ṁ = Q / (Cp × ΔT), where Q is the total heat duty, Cp is the oil's heat capacity and ΔT is the difference between supply and return temperatures. A typical ΔT for mineral oils is 20–60 °C.

The expansion tank (or expansion vessel) must hold the volume increase when the oil heats from cold-fill temperature to operating temperature: V_exp = V_system × β × (T_avg − T_cold). For mineral oils β is about 0.0007 /°C; a common rule of thumb is to size the expansion tank at 25–30 % of the total system volume.

The film temperature at the heater tube wall is the most critical limit in a hot oil system. If the film temperature exceeds the oil's maximum, the oil cracks, cokes the tubes and degrades rapidly. The film temperature is estimated as T_film = T_bulk + q″ / h_film, where q″ is the heat flux (kW/m²) and h_film is the oil-side film coefficient. Keeping the velocity above 1 m/s and the heat flux below the oil maker's limit are the main safeguards.

Example: 500 kW duty, Therminol 66 at 300/250 °C (ΔT = 50 °C): circulation rate 4.76 kg/s = 19.7 m³/h. With 5 m³ system volume the expansion from 15 °C to 275 °C average is 0.91 m³ (18 % of system volume). At 25 kW/m² heat flux and 500 W/(m²·K) film coefficient: T_film = 300 + 50 = 350 °C, below the 380 °C limit with a 30 °C margin. In a 150 mm pipe the velocity is 0.31 m/s — too low; a smaller pipe or higher flow is needed.

Limits: the oil properties built in are typical values at the upper operating range. Actual Cp and density vary with temperature; use the oil maker's data sheet for detailed design. The film temperature estimate assumes a uniform heat flux; real heaters have a distribution — the peak flux sets the limit. This calculator does not size the heater, piping or pump; it gives the basic parameters for screening.